Navigate to the Cable Maintenance Grid. Main > Cable > Cable Maintenance (see Cable module navigation).

...

To add a new cable to the Cable Maintenance Grid, click theAddImage Modified button on the Grid Toolbar above the Grid. This opens a Cable Maintenance data entry form.

The User must first input data into the Required fields. In this case, the User must input the Cable Name and choose a Cable Type from a drop-down list of default options. At this point, the User can choose to add in-depth identification information, including Length (feet) and Signal Loss (decibels). The greyed-out data fields are automatically generated when the User adds specific Pairs/Strands to the newly created cable.

Include Page
Add New Cable
Add New Cable

Saving a New Cable

Upon fulfilling all the Required fields, clickSave NewImage Modified at the bottom of the Cable data entry form. This action results in three distinct outcomes. First, the new Cable is visible in the original Cable Maintenance Grid. Second, the PCR-360 application automatically generates inputs for the greyed-out data entry form data fields referenced in the Adding a Cable section. Most importantly, the PCR-360 application automatically generates the new cable's pairs/strands information in a previously absent data entry form tab entitled Pairs and Strands (see Managing pairs and strands below).

Bulk Adding Pairs/Strands to a Cable

Considering the high volume of Cables employed by a modern business, it is typically much easier to manage Cables in bulk. To bulk Create or Edit Pairs/Strands, select the cable in the Cable Maintenance grid, and click the Image Modifiedbutton. Then use the section labeled Pairs/Strands.

In this section, the User can input the new cable's origination and destination equipment – that is, what the cables are plugged into on either end. To select a piece of origination or destination equipment, click on the Search Icon (Image Modified) in the 'Equipment' data field. This opens a list of the User organization's Equipment from which the User can select the appropriate equipment.

Search IconImage Removed

Once the User has defined the appropriate origination and destination equipment, the next step is to define the number of Pairs/Strands and add further identification information. In the data field labeled Low, enter the '1' to indicate that there is at least one strand/pair in the cable. In the data field labeled High, enter the maximum number of strands/pairs that is applied to the cable. For example, if a User wants to input 10 strands/pairs, the appropriate Low/High input would be 1/10.

...

After the User indicates the number of Pairs/Strands applied to the cable, the Cable data entry form automatically updates to reflect the changes. The 'Status' drop-down menu, for example, becomes a Required field as well as the Origination Equipment from which the pairs/strands begin. Critically, the tab labeled 'Pairs/Strands' also appears and lists each pair/strand in a Grid format (see Managing pairs and strands below).

Status

More information on Pair/Strand statuses is available here

...

This button allows the User to Transfer a range of existing Pairs/Strands from one Cable to another.

  1. To access this form, from the Cable Maintenance grid, click the Image Modified button.

  2. This brings up the 'Manage Cable' dialog.

    Manage Cable formImage Modified
  3. Select the Cable to transfer to.

          Cable Name picker

       4. Select the Low range to be associated with the moved Cable.

         Low fieldImage Modified

       5. Click the SaveImage Modified button.

All Pairs/Strands in the range will be transferred from the Origination (Transfer from) to the Destination (Transfer to) Cable.

...

The 'Access Points' tab allows the User to associate Access Points with a Cable. The User can 'Add' a new Access Point from this tab or 'Add Existing' Access Point(s) from the Access Points Grid.

Add

  1. Click the AddImage Modified

...

  1. button.

  2. This opens the 'Add New Access Points' form.

    Add New Access Points formImage Modified
  3. Enter the information into the fields if desired.

  4. Click the Save NewImage Modified button.

The Access Point is added to the 'Cable' as well as the Access Points Grid.

Add Existing

  1. Click the Add ExistingImage Modified button.

  2. This opens the 'Existing Access Points' form.

    Existing Access Points formImage Modified
  3. Select the Access Point(s) desired.

  4. Click

...

  1. the Save and CloseImage Modified button.

The Access Point is added to the 'Cable' from the Access Points Grid.

...

The 'Conduit' tab allows the User to associate Conduit with a Cable. The User can 'Add' a new Conduit from this tab or 'Add Existing' Conduit from the Cable Maintenance Grid.

Add

  1. Click

...

  1. the AddImage Modified button.

  2. This opens the 'Add New Cable' form.

    Add New Cable formImage Modified
  3. Click the Save NewImage Modified button.

The Conduit is added to the 'Cable Maintenance' as well as the Conduits Grid. When Conduit is deleted from the Cable Maintenance Grid, the Conduit remains on the Conduits Grid since there is only an association record on the Cable Maintenance Grid.

Add Existing

  1. Click the Add ExistingImage Modified button.

  2. This opens the 'Existing Conduits' form.

    Existing Conduits formImage Modified
  3. Select the Conduit(s) desired.

  4. Click the Save and CloseImage Modified

...

  1. button.

The Conduit is added to the 'Cable Maintenance' from the Conduits Grid.

Child pages (Children Display)
styleh6
sorttitle