Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Table of Contents
outlinetrue
stylenone

...

This tab will only be available on (2024.1) Equipment types that have Cabling associated with the piece of Equipment.

...

Assuming a prefix Range of 1-3, a separator of " - ", and a low to high suffix of 1-5 the User would be adding 15 records with the 'Save New' button  . In this case the following would be added:

Example Ports/Pins/Lens

Suffix of '1'

Suffix of '2'

Suffix of '3'

Suffix of '4'

Suffix of '5'

Prefix of '1'

1-1

1-2

1-3

1-4

1-5

Prefix of '2'

2-1

2-2

2-3

2-4

2-5

Prefix of '3'

3-1

3-2

3-3

3-4

3-5

The 'Ranges' is more than a simple Add form, however, and will allow the User to edit multiple PPL. If after adding the above table the User were to click the Ranges button again and enter a prefix of 2-3, and a suffix of 1-1 they would select the 2-1 and 3-1 PPL for editing. This functionality allows the User to quickly Add and assign status' to multiple PPL.

...

To Transfer PPL follow these steps:

  1. Click the 'Transfer' Image Modified button.

  2. This will open the 'Add new Select Equipment and Range to Transfer (move) the Ports/Pins/Lens' form. (Transfer PPL form for short.)

...

  1. The 'Origination Equipment' picker will automatically fill in with the Equipment from the open Equipment form.

  2. Click the 'Destination Equipment' picker and select the Equipment that the PPL need to be transferred to.

  3. Select a Destination piece of Equipment that is different from the Origination Equipment.

  4. Select the Origination Port/Pin/Len Range.

    • Enter the Low PPL of the PPL records that should be selected to Transfer. This needs to include the proper format for the PPL based on the organizations naming conventions. For example, if the Low PPL is named "123-ABC" where "-" is the separator, then the formatting should look like this: Low Separator: 123, Separator: -, *Low Suffix:*ABC.

      Image Modified
    • Enter the High PPL of the PPL records that should be selected to Transfer. This needs to include the proper format for the PPL based on the organizations naming conventions. For example, if the High PPL is named "124-ABZ" where "-" is the separator, then the formatting should look like this: High Separator: 124, and *High Suffix:*ABZ.

      Image Modified
  5. Select the Destination Port/Pin/Len Range.

    • Enter the Low PPL of the PPL records that should be created on the new Equipment record after the Transfer. This range should be set in the same manner as previously discussed.

      Image Modified
  6. Click the 'Transfer Range' Image Modified button.

The selected range will transfer to the Destination Equipment.

...

To Transfer a PPL Range, follow these steps:

  1. Click the Transfer Range button. Image Modified

  2. This will open the Add New Select Equipment and Range to TRANSFER (move) the Ports/Pins/Lens form. (PPL Range Transfer Form for short.)

    Image Modified
  3. The Origination Equipment picker will automatically fill in with the Equipment from the open Equipment form.

  4. Click the Destination Equipment picker and select the Equipment that the PPL need to be transferred to.

  5. Be sure to select a Destination piece of Equipment that is different from the Origination Equipment.

    Image Modified
  6. Select the Origination Port/Pin/Len Range.

  7. Enter (at minimum) Low Prefix and High Prefix of the PPL records that should be selected to Transfer.

    Image Modified


    1. Separator, Low Suffix, and High Suffix are optional fields that increase the flexibility of ranges.

    2. This needs to specify the proper format for the PP. Generally, this format is based on the organization's naming conventions.

    3. For example, the range shown above represents Low PPL named A-01 with a range of 30 ports ending on C-10.

      Image Modified
  8. Select the Destination Port/Pin/Len (PPL) Range.

  9. Enter (at minimum) the Low Prefix of the port range the newly transferred PPLs will start at.

    Image Modified


    1. Separator and Low Suffix are optional fields that increase the flexibility of ranges.

    2. This needs to specify the proper format for the PP. Generally, this format is based on the organization's naming conventions.

    3. For example, the range is shown above (in conjunction with the Origination Range) represents Low PPL named D-11 with a range of 30 ports ending on F-20

  10. Click the Transfer Range button to complete the transfer

  11. The selected range will be transferred to the Destination Equipment with the specified new starting port 

Transfer All

The Transfer All button  allows transferring every PPL on an Origination Equipment to a Destination Equipment. The purpose of the form is to eliminate a few steps when the user simply needs to move ALL of the ports.

To transfer all PPLs on Equipment, use the following steps.

  1. Click the Transfer All button. Image Modified

  2. The Origination Equipment picker will automatically fill in with the Equipment from the open Equipment form.

  3. Select the Destination Equipment Using the picker

  4. Click the Transfer All Ports/Pins/Lens button to complete the transfer Image Modified

  5. All PPLs will be transferred, as is, to the Destination Equipment.

    Image Modified

Renumber

Users can quickly renumber PPL with the Transfer form.

  1. Click the 'Transfer' Image Modified button.

  2. This will open the 'Add new Select Equipment and Range to Transfer (move) the Ports/Pins/Lens' form. (Transfer PPL form for short.)

    Image Modified
  1. The 'Origination Equipment' picker will automatically fill in with the Equipment from the open Equipment form.

  2. Click the 'Destination Equipment' picker and select the Equipment that the PPL need to be transferred to.

  3. Select a Destination piece of Equipment that is the same Equipment as the Origination Equipment.

  4. Select the Origination Port/Pin/Len Range.

    • Enter the Low PPL of the PPL records that should be selected to Transfer. This needs to include the proper format for the PPL based on the organizations naming conventions. For example, if the Low PPL is named "123-ABC" where "-" is the separator, then the formatting should look like this: Low Separator: 123, Separator: -, *Low Suffix:*ABC.

      Image Modified
    • Enter the High PPL of the PPL records that should be selected to Transfer. This needs to include the proper format for the PPL based on the organizations naming conventions. For example, if the High PPL is named "124-ABZ" where "-" is the separator, then the formatting should look like this: High Separator: 124, and *High Suffix:*ABZ.

      Image Modified
  5. Click the 'Transfer Range' Image Modified button.

The selected Range will be renumbered and remain on the original Equipment record since the Origination Equipment and Destination Equipment fields match.

...

The 'Edit Selected' button  will allow the editing of a single PPL record. A User can only edit the single record, and if multiple records editing is desired the Ranges button should be used.

Delete Selected

...

The 'Service Desk' button  will open the Service Desk Action associated with the PPL. This button will only open the Service Desk Action once the PPL has its Status effected by the Service Desk. Once a PPL has been designated in Service Desk, it cannot be selected to be added to a different piece of Equipment. This helps to prevent duplicate assignments.

View Path

  • The View PathImage Modified

     button

    button will open up the Cable: View Path report that the given Ports/Pins/Lens record appears on.

  • For a Ports/Pins/Lens record to have a Path associated with it it must first have a Status of Assigned.

  • more Information about paths and the report is available here

Child pages (Children Display)
styleh6