Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Scroll Health Check: The link has been rewritten to its master page by check 'P16'.

Table of Contents
outlinetrue
stylenone

...

Parameter

Required

Data Type

Options

Notes

eqp_catalog

Yes

Integer


RECID of the Equipment's Equipment Catalog.
quantityNoInteger
This represents both Units and Quantity. If the Equipment Catalog Has Units - it is Units - if it is marked as "not units" then it is recorded as Quantity in the application currently.
from_locationYesInteger
Location RECID of the Warehouse of the Equipment is from.
to_locationYesInteger
Location RECID of the Warehouse of the Equipment is going to.
recidsNo*Array
Conditionally Required if the Equipment is an Asset . An array of Asset Tags, Serial Numbers and/or Equipment IDs (id # on the equipment record)or Cabling. Sent as an array of recids. See the Notes section below for more details.
commentsYesString
The reason why the Equipment is being transferred.

...

Equipment,
Note: that this will default to 1 for units catalogs. It is ignored for non-unit catalogs

Parameter

Required

Data Type

Options

Notes

recid YesInteger
Purchase Order RECID, Status must be Open
eqp_catalogYesInteger
Equipment Catalog RECID
priceYesFloat
Price of Equipment
unitsNoInteger
Units of Equipment. Only valid for Has Units Equipment, else ignored. The value must match an entry on the Purchase Order Equipment, as PCR-360 uses this to detect which item is being received if there is more than one entry for the Equipment Catalog on the Purchase Order and their units are different.
quantityYesInteger
Quantity to Receive
locationYesInteger
Valid Active Warehouse RECID to receive Equipment
received_dateNoDate
Received Date
assetsNoArray
Only valid for Asset or Cabling Equipment, else ignored. If provided the number of entries must match the quantity.


Request Example

Call
Code Block
languagesql
http://DOMAIN/api/API_KEY/barcode.OUTPUT

...

Parameter

Required

Data Type

Options

Notes

scan_dateNoDate
Expected format: YYYY/MM/DD
eqp_catalogYesInteger
Equipment Catalog RECID
unitsNoInteger
Units of Equipment,
Note: that this will default to 1 for units catalogs. It is ignored for non-unit catalogs
quantityYesInteger
Quantity to Receive
locationYesInteger
Valid Active Warehouse RECID to receive Equipment
assetsNoArray
Only valid for Asset or Cabling Equipment, else ignored. If provided the number of entries must match the quantity.

...