Ports/Pins/Lens Imports
Capability
The Ports/Pins/Lens Import will INSERT and UPDATE Ports/Pins/Lens on Equipment records.
Matches On
To find an existing Ports/Pins/Lens record, you can use the Ports/Pins/Lens RECID, or you can identify the Equipment and Port.
To identify the Equipment, you can use any of these fields:
- Equipment RECID
- Asset Tag
- Equipment ID and Equipment Location
- Serial Number
- MAC Address
To Identify the Port you need the Port Name and Port Side.
Fields
Equipment RECID
Datatype is Number.
If this is provided, then the Equipment with that RECID must exist.
Asset Tag
Datatype is String.
Equipment ID
Required
Datatype is String.
Equipment Location
Datatype is String.
Serial Number
Datatype is String.
MAC Address
Datatype is String.
Port/Pin/Len
Required
Datatype is String.
Port Side
Required
Datatype is String.
Permitted values are from the PORT_SIDE List Values : Front, Back, Cross-Connect, and N/A.
Any values added by a User to the PORT_SIDE list can also be used.
Port Alias
Datatype is String.
Pair Status
Required
Datatype is String.
Permitted values are from the PAIR_STATUS List Values : Left In, Spare, Assigned, Reserved, PDPC, Pending Disconnect, Pending Connect, Bad, and Unknown.
Any values added by a User to the PAIR_STATUS list can also be used.
Equipment Location
Datatype is Hierarchical String.
The Equipment Location is only used to find the correct Equipment. It is only needed if there are more than one Equipment with the same Equipment ID in different Locations.
Equipment Location Type
Datatype is String.
Permitted values are from List Values of type LOCATION_TYPE: Site, Building, Floor, Room, Cube, Truck, Closet, Rack, Elevation, or Manhole.
The Location Type is only used to find the correct Location. It is only needed if there are more than one Location with the same Name with different Location Types.
User entered values to the LOCATION_TYPE list may also be used.
Multiple Paths
Datatype is Boolean.
Default value = False [0].
Port Tx Rx
Datatype is String.
Permitted values are from the PORT_TX_RX List Values : TX, TX/RX, RX, and N/A.
Any values added by a User to the PORT_TX_RX list can also be used.
Port Type
Datatype is String.
Permitted values are from the PORT_TYPE List Values : BNC, FC, SC, LC, WW, RJ11, RJ45, and N/A.
Any values added by a User to the PORT_TYPE list can also be used.
Port Speed
Datatype is List.
Default value is blank.
Permitted values are from the PORT_SPEED List Values : 10 Mbps, 100 Mbps, 1 Gbps, Auto, Auto-10, and Auto-10-100.
New Port/Pin/Len
Datatype is String.
This field is used to rename a Port.
New Port Side
Datatype is String.
This field is used to change the Side of a Port.
VLAN
Datatype is String.
Default value is blank.
Attaches a VLAN to the port.
If the provided VLAN does not exist, it is created.
VLAN Description
Datatype is String.
Default value is blank.
Only used on new VLAN creation.
If the VLAN already exists, this is ignored. It will not update.
Flags
REPLACE_VLANS
Default value is False
- True: when a new Vlan value is provided to a Port, all of the existing Vlans on that port will be removed.
- False: when a new Vlan value is provided to a Port, all of the existing Vlans on that port will be appended.
Errors
When an Import Line fails, it is usually because the Line falls into one of the following categories:
A blank value was provided, for a field with a required value
The value provided was not found in the database
The System was unable to save the record
Notes
The Ports/Pins/Lens Import does not create the Equipment. Equipment MUST already exist to associate Ports/Pins/Lens to be associated with it.